Our Electrical inspection & testing services
(periodic test or installation certification)
Electrical inspection & testing (periodic test or installation certification)
Did you know that an electrical installation has a average life of 40 years.
And this is not based on extreme weather (heat environment) conditions that prevails on our islands.
Did you know that according to the NEN 1010 standard that must be used for low voltage installations,
inspections before completion and after completion of an installation must be made.
Regarding the safety of your fellow employees and relationships, and your legal liability
(think of your ultimate liability), you are required to a regularly check of your electrical installations for defect.
Key benefits of inspection
It is better to prevent than to remediald after defect is done.
You can save on greater investment by earlier detection and solving of the problems in your electrical system
You can prove your insurance company that you did everything you can for the good working of your
installation system. (This in case of fire)
Services that we can offer you
Inspection of new electrical installation before your certification.
Inspection of existence electrical system (NEN 1010, NEN3140/EN50110).
Thermal imaging inspection.
ATEX 137 Inspection of explosion-proof installation
Inspection of new installations / test is the electrical network is correct for Certification for D.O.W (NEN 1010 part 6)
We can inspect and certify your electrical installation according NEN1010 Part 6.
Every electrical installation during installation and befor the user take it in operation, it must be visually inspect
and measurement tested, this to determine if the installation met the minimum requirements of the standard NEN1010.
The findings of the inspection are recorded in a report that is preserved by the system administrator.
Depending on the nature of the business, the electrical installations must be inspected on average
once every five years.
We identify and make a plan in advance of the electrical installations. Next, we will consult with
you a plan that will be execute during the inspections.
After the inspection, the inspector will hands on a pre draft report. This concept will be discussed, and
the final report will be produced and present in the week to come.
Inspection of existence installations (NEN 1010, NEN3140/EN50110).
IBTIKAR Advisors can inspect your electrical installation according to NEN3140 / EN50110. (excluding labor devices).
According to NEN 3140, existing electrical installations must be periodically inspected. The inspection of the electrical
installation must be carry out according to security standards used when electrical installation was installed for the first time.
But if in years after the first installation, changes have been made at the installation,the inspection must be carryout according
to the new standard ad that moment.
The findings of the inspection are recorded in a report that is preserved by the system administrator.
Depending on the nature of the business, the electrical installations must by inspected on average once every five years.
We identify and make a plan in advance of the electrical installations test or measurements. Next, we will consult with you a
plan that will be execute during the inspections.
After the inspection, the inspector will hands on a pre draft report. This concept will be discussed, and the final report will be
produced and present in the week to come.
We aim as much as possible that during the inspection your business will not suffer any loss of time or trouble.
Thermal imaging inspection.
Electrical Thermal imaging is used as a visual inspection method based on heat appearance of objects.
Using a thermal imaging camera is heat appearance of objects visible.
Our company has the necessary specialist knowledge to interpret the infrared images obtained by an thermal imaging camera.
We are therefore capable to investigate and advise you appropriately the best way for the reliability of your electrical and fire
safety system.
Why Thermal imaging research?
To ensure continuity of your installation is thermal imaging study a must.
Thermal imaging research will take place during normal production, and will hardly lead to
disruption of your production.
The measurements can be carried out quickly, which in a short time you can obtain a clear view of
the condition of the electrical installation.
The thermal imaging inspection is performed without direct contact with live parts and is therefore
applicable to difficult places.
The inspection
We identify and make a plan in advance for the electrical installations thermal imaging inspection.
During the inspection of all parts, infrared shots from the objects will be made.
All doors and cover have to be open also protective hood / cover or shield must be removed.
Al reference are normal digital images made of the investigated site.
We prefer that the system runs ad here maximum capacity for a good description (view) of the condition of
the installation.
ATEX 137 Inspection of Atmospheres EXplosives Installations
For all areas with potentially explosive atmospheres, M adies & ontwerp inspect this periodicly according
to
ATEX 137 standards. The term ATEX is composed of the French words Atmospheres EXplosives.
The goal of the ATEX inspections is to protect the workers so that they can work without risk.
Some examples of places where ATEX inspection is required:
● Cars spray cabinets/Automotive paint booths
● Offshore Platforms
● Milk Powder Plant
● Basement vulture
● battery charging room
● Area where generators are in located
● Storage space for paint, fireworks, corn storage room and so on.
Do to our extensive experience in the offshore industry (petrochemical, dairy powder,
paint factories, bakeries, etc.) we can inspect your system with great expertise.
Rapportage
All final report shall or will shows the current state of the studied objects, taking as reference the
thermal imaging inspection if this was required in your quotation.
The identified components or the defects in your installation during the measuremends, test or inspections
should be change to reduce risk of any type according to the level of risk.
The report covers all elements investigated, so that by a examination in the future, they can be used as a reference.
IBTIKAR